Doubel Combustion Chamber
All Incinerators are Doubel Combustion Chamber with One Fuel Burner Each. After Burner Technology for Completely Combustion and Cleaner World.
Read MoreHigh Temperature Incineration
Temperature Range 800 Degree to 1200 Degree in Combustion Chamber. Temperature Thermocouple Monitor and Controller. High Quality Fire Brick and Refactory Cement.
Read MoreGet Lastest News
There are latest incinerator news like technical, public news, business tender for medical waste incinerator,animal incineration, pet cremation
Read MoreNanjing Clover Medical Technology Co.,Ltd.
Email: sales@clover-incinerator.com | Tel: +86-25-8461 0201
Regular model incinerator for market with burning rate from 10kgs to 500kgs per hour and we always proposal customer send us their require details, like waste material, local site fuel and power supply, incinerator operation time, etc, so we can proposal right model or custom made with different structure or dimensions.
Incinerator Model YD-100 is a middle scale incineration machine for many different usage: for a middle hospital sickbed below 500 units, for all small or big size family pets (like Alaskan Malamute Dog), for community Municipal Solid Waste Incineration, etc. The primary combustion chamber volume is 1200Liters (1.2m3) and use diesel oil or natural gas fuel burner original from Italy.
Latest Post
laboratory incinerator
the entire carcass of animals ( cattle , horses ,
Sheep, pigs , etc.) , as well as biologically hazardous waste
Products in the fuel stove .
? Opening Doors – the closure and fixation automated system ,
Which are managed remotely by the operator .
? designed to work in long mode and fast
Action ( Quick Start EP – i)
? Fully mobile – mounted on wheeled chassis
Even during the operation . Incinerators must be provided
As standard equipment a special truck
air retention for at least 2 seconds at a temperature of less than 850C, the combustion
In order to achieve the proper effect.
? must be a two-chamber incinerators, primary and secondary
Fuel stoves
? The waste products to reduce the initial volume
Possible to minimize (approximately 5% sterile ash
Form).
Incinerators should be provided in the fuel tank (diesel )
? The minimum capacity of the animal carcass incinerator
The destruction of 1000 kg / hour. Incinerator capacity is calculated
8MJ/kg- material and 60 % humidity.
? It must be possible to use the incinerator +40
C to – 15 0C laboratory incinerator
Temperature and 5% – 95% – of moisture conditions.
? PLC controller and a built-in temperature panelita complete
Automatic control, a control computer, which is stored
Information on the variation of temperature with respect to time and
Graphic images.
? must have fuel with automatic control and malfunction
Detection system.
?the ability to pre- warm-up , body waste burning on and off
Consistency is independent of the first and secondary chambers.
? ensuring the incinerator with electricity , it
Must be installed on the generator.
? clean the incinerator should be simple tools ,
Without using any additional equipment
medical incinerators
● Able to burn 25-30kg per hour
● Consist of two chambers to ensure significant reduction in emission
● Be capable of temperature in range of 800c to 1000c
● Low maintenance design
● Must be Diesel fuelled
● Need more than 15amp 220- 250V power
● kW Consumption power consumption to be stated
● Onboard or in-built fuel storage storage tank & should use no more than 12L of dies el per hour to burn 25-30kg of waste
● Solid waste reduction in range of 90-97% ( should be routinely achieved)
· General wastes produced on a daily basis include paper, plastic, organic materials, boxes, plastic containers, leaves, etc;
· Total waste produced per day: 10-12 tonnes;
· Hours of Operation: 10 hours a day;
· Fuel requirement: Diesel or waste oil preferred but LP gas will be considered;
Fuel options Oil
Fuel consumption (diesel) 10 litre/hour
Average Capacity 900kg
Diamention: Length (mm)
Width (mm)
Height Excl. Flue (mm)
Door Opening (mm) 2570
1120
1340
1000×1670
Internal Chamber Dimen:
Length (mm)
Width (mm)
Height Incl Flue (mm)
2200
790
790
Operation:
Min. Operation Temprature
Max. Operation Temprature
Residence Time in Second Chamber
Temprature Monitoring
950
1320
2 sec.
YES
Key Features
-Auto ignition
-Automatic control and temprature
-Upto 250 kg per hour
-Thick refratory lining rated to 1600 deg C in main chamber retain heat, increase efficiency
-Heat resistant 5 mm steel
-Stainless steel stack
-12 cm of refractory lining- steel reinforced.
-12 month or 1000 hours waranty
-Heat recovery system
-Wide door for ash removal
-Large top opening lid for easy loading
small scale incinerator
Incinerators Biological waste disposal system (incinerator)
Incinerator must meet the following specifications:
– Combustion capacity (kW) = 581 +/-10%
– Combustion capacity (kcal/h) = 500,000 +/-10%
– Max. l/h (at approx.. 50% water content) = 100 +/-10%
Further specifications will be provided with the inquiry.
The incinerator shall be fully self contained.
The incinerator plant shall incorporate a control panel for its operation. On the control panel we shall have a visual display of the chamber temperatures. This visual display must control and monitor the incinerator and his performance.
Capacity of destruction in weight shall be 60 Kg/h.
It should be able to operate not less than 10 hours/day
This incinerator must be able to destruct all combustible wastes produced by hospitals, private clinics, laboratories, institutes, etc…
Design Specification : Types A, B, C, D, and E of medical waste
“PYROLYTIC” combustion, by controlling the gasification of waste.
The incinerator must avoid the release of black smoke and fine dust, during the loadings.
It shall be able to reduce the volume of wastes by 98%.
It shall be able to hold emission in the second burn with gas residence of not less than 2 seconds.
The incineration should be completely free from visible smoke as well as offensive odours.
1.0The primary ignition burner shall providing ignition of the waste to 850 °C and must switch off to conserve fuel.
The primary combustion chamber shall be constructed from heavy steel plate and the unit is internally lined with a complete layer of hote face refractory and high efficiency insulation.
The Internal diameter of the Chimney at least: ? 400 and its height: 8 m
The Volume of the combustion chamber at least: 1.200 L
The Dimension of the door for loading in cm at least: 70×70.
Burner operation should be Automatic On/Off
Fuel?: diesel
Manufacturer to provide necessary information for the best of the installation
The control panel shall have all appropriate audible and visual alarms to ensure safe operation.
This incinerator with “PYROLYTIC” combustion must have:
1.A combustion chamber of waste:
oPerfectly tight door for the manual loading of waste. The loading should be Manual, Batch Load
oA burner of lighting which the use is limited to the ignition of waste.
oFrontage of loading with door seals gone up on hinges, wheel of screw plug, flexible joint, and stuffing insulating out of refractory.
oThe insulation of the combustion chamber should be composed of refractory bricks, having a high content of aluminium and insulates bricks in order to assure a minimum temperature on the outside sheet metal.
o Composition of the refractory;
?Refractory concrete :
. Thickness : ≥100 mm
. Nature: 42% of Al203
?Insulate in fibrous panels :
Thickness: ≥75 mm
Nature: Calcium silicate.
?Burner of lighting of waste, with fuel, standard mono-bloc casting guiding plunging flame, lighting and safety of electronic ignition, permanent ventilation, electromagnetic sluice gate of regulation and isolating valve.
Plate of combustion in Carborundum, avoiding the fixing of glass and slags
A chamber of post combustion of gases
oA burner of combustion of gases,
oA device of injection of air allowing a total recombustion of gases,
oA device of air inlet of cooling of waste gases,
oA sheath of evacuation of the gases burnt.
oCarcass in strong sheet steel with support of connection.
oComposition of the refractory;
?Refractory concrete :
?Thickness : ≥150 mm
?Nature: 65% of Al203
?Insulate in fibrous panel :
?Thickness: ≥85 mm
? Nature: Calcium
oBurner with fuel, mono-bloc casting guiding type with horizontal flame, lighting and safety of electronic ignition, permanent ventilation, electromagnetic sluice gate of regulation and isolating valve.
oA secondary injection of air to ensure perfect oxygen content.
A control box ensuring the complete cycle of combustion.
Fan:
oElectro-ventilator distributing the secondary air, the regulation of the air flow being carried out by valves and following the control of the automatic cycle.
Controls and regulations:
Control box watertight to dust, including:
A switch circuit breaker for each engine (ventilators and burners).
A timer with adjustable temporization for the regulation of each burner.
A regulator with digital watching for the temperature of combustion.
A regulator with digital watching for the temperature of post combustion.
Electric box
The secondary combustion chamber must destroy the contaminant product and must resist to high temperature(1100 °C)
Process Filtering system: Scruber to be mentionned as optional
animal incinerators for sale
SMART ASH INCINERATORS FOR THE DISPOSAL OF HAZARDOUS WASTE
? Quantity: 20 units
? The Incinerator works with a 55 gallon open ended steel drum
? The unit operates without fuel and used only 120v or 220v electricity for the blowers
? Unit is capable of burning oil contaminated waste and medical wastes with a moisture content of 0 to 15%
? Each unit is supplied with two steel drums, so that a spare is available
? Each unit to be supplied with recommended spare parts
? Warranty – minimum 12 months from receipt and acceptance
? Instruction manuals to be provided in French and English
HAZARDOUS WASTE TO BE INCINERATED
Hazardous Solid Chemicals
Different types of combustible solids, used textiles, grease and toner cartridges, chemicals for water purification and photographic consumables, and plastic material, empty metal/ plastic cans that still contain remnants of hazardous materials, oil absorbent
Hazardous Liquid Chemicals
Mainly different types of Acid, Paint, Varnish, White Spirit, Aromatic-Less Solvents, Synthetic Liquid For Brake Systems, Aircraft De-icing Liquid, Hydraulic And Compressor Oil, Freon used in some older refrigeration units, Insecticide Liquid/Spray, Air Refresh Spray and other similar chemicals
Contaminated Fuel
Mainly diesel or gasoline contaminated by water or solvents
Used and/or Contaminated Oil
Used motor oils and/or mineral oils unfit for their originally intended use. Mainly motor/gear box oil (approx. 80%) contaminated by a mixture of white spirit and acetone (approx. 5%) hydraulic liquid (approx 5%)
Contaminated Water
Waste oils/water, leaches, hydrocarbons/water mixtures, emulsions and leachate
Contaminated Soil
Soil polluted by oil fuel of chemicals,
Soil polluted that has to be recycled in landfill,
Soil treated and replaced on site
Oil Contaminated Solids
Rags, absorbents, cardboard, oil and fuel filters, air filters are not considered as hazardous materials
Electronic Waste
Waste electrical or electronic appliances or assemblies, including printed circuit boards containing toxic material and/or heavy metal and/or emitting low radiation
Used Battery Cells
Dry battery, ups battery or other types unsorted waste batteries/battery cells, containing materials that are hazardous
Used Lead Acid Batteries
Waste lead acid batteries, drained/ un-drained and whole or crushed
Hazardous Medical Waste
Clinical and related waste arising from medical, nursing or similar practices and waste generated in clinics during the investigation or treatment of patients (bio hazard)
Expired Drugs Solid
Waste pharmaceuticals, drugs and medicines, including sensitive medicines
Expired Drugs Liquid
Waste liquid pharmaceuticals, different type liquid chemicals for treatment, medical grease and paraffin based expired medicines
Expired and/Or Contaminated Food
Spoiled fresh food or unusable meal ready to eat meals (MRE’s) dry food
waste incinerator
Burring Capacity 100 / 200 KG/ hr Please write your offer here
Number of Burner 02 Nos Please write your offer here
Incinerator Type Dual Chamber
Primary Chamber
Secondy Chamber Please write your offer here
Incinerator Design Controlled Air Please write your offer here
Fuel to be used Natural Gas / Deisel Please write your offer here
Loading System Manual / Batch Type Please write your offer here
Warmer Time 20 minutes Please write your offer here
Type of Paint Heat Resistance enamel paint Please write your offer here.1. Petrol: diesel
2. Consumption: 8-10liter/hour
3. Capacity: to cremate (carrion and spoils) 350-400kg/hour
4. Temperature: 900-1350?C
5. Operation temperature: -30~40?C
6. Incinerator weight: 1800-2000 kg
7. Volume: 0.70-0.80m/cube
8. Exterior dimension: 1.4-1.6*1.0-1.15m (L*W)